FLUKE MICROSCANNER2 MANUAL PDF

get started using the tester. For additional information, see the MicroScanner2 Cable Verifier. Users Manual on the Fluke Networks website. Safety. Warning. MicroScanner2 Cable Verifier. Accessing the Users Manual. This guide provides basic information to help you get started using the tester. For additional. View and Download Fluke MicroScanner 2 user manual online. Cable Verifier. MicroScanner 2 Test Equipment pdf manual download.

Author: Shakajin Kagashakar
Country: United Arab Emirates
Language: English (Spanish)
Genre: Personal Growth
Published (Last): 13 July 2017
Pages: 443
PDF File Size: 10.36 Mb
ePub File Size: 13.46 Mb
ISBN: 179-2-99785-459-5
Downloads: 83228
Price: Free* [*Free Regsitration Required]
Uploader: Sabar

Connect the tester to the cable. The rightmost segments indicate the shield. Table of Contents Add to my manuals Add.

Toning in IntelliTone™ Mode – MicroScanner2

Use the tester to check for shorts. Figures 1 and 11 show examples of this occurs, clean with water and get medical aid.

LEDs show kanual wiremap. The pin numbers flash to indicate the fault. The cable length is By pressing ‘print’ button you will print only current page. Telephone cables wired in a star topology Figure 16 are connected together at a bridge tap at the distribution If you connect kanual tester to the bridge tap, the tester center. Page 60 MicroScanner Cable Verifier Users Manual split pair, 15 telephone voltages, 16 —U— universal adapter, 10 —V— version information, 41 voltage detection, 5, 16 —W— wiremap adapter, Adrian Young Creation Date: Navigates through screens and changes settings.

FLUKE MICROSCANNER 2 USER MANUAL Pdf Download.

Performance Specifications The wiremap is drawn with proportional length to visually indicate the approximate location of faults. Fault Locators and Tone Generators. Using the Toner You can use the tester with an optional tone probe to locate cables in bundles, at patch panels, or behind walls. Index microscanner22 tests Symbols coaxial cabling, 28 “? Versiv Cabling Certification System.

TOP Related Posts  DIDYSIS GETSBIS PDF

Fluke MicroScanner 2 User Manual

Table of Contents Title Page Introduction Integrity Networks Alaska Branch. For a correct length reading, connect the tester and wiremap adapter as shown. MicroScanner Cable Verifier Users Manual The tester cannot measure length past the bridge tap Connecting to Telephone Networks Wired in because reflections from the bridge tap connections Star Topologies interfere with measurements. Page 34 – Connecting to Telephone Networks Wired i Index Index cable tests Symbols coaxial cabling, 28 “?

See explanations in the manual.

Open on Coaxial Cabling egk Fiber Inspection and Cleaning. Only the first bridge tap detected is reported. Notes If you cannot locate the IntelliTone signal on 2-conductor cables, the cable may be shorted. This equipment is intended for Fluke Networks. MicroScanner Cable Verifier Users Manual Regulatory Information This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the manual, may cause interference to radio communications.

Using the Toner in IntelliTone Mode. Press PORT to select twisted pair or coaxial cable. If Table 2 does not help you solve a problem with the tester, contact Fluke Networks for additional help. Fuke connectors F-connector for coaxial cable. Length is not shown because the voltage interferes with length measurements.

Use the probe to search for the cable. The display shows the song number 3. Page 59 Index testing —R— coaxial cabling, mlcroscanner2 registration, microscahner2 twisted pair cabling, 11 remote ID locator, 10, 22 toner, 32 replacement parts, 42 analog mode, 35 RJ11 jack, 10 IntelliTone mode, 32 SmartTone function, 35, 36 —S— troubleshooting safety information, 3, 39 cabling faults, 47 serial number, 41 the tester, Note Use the SmartTone function only on dry pairs of wires that are unterminated at both ends.

TOP Related Posts  KANDHA SASHTI KAVASAM TAMIL PDF

Welcome f,uke Fluke Networks. Regulatory Information MicroScanner Cable Verifier Users Manual Regulatory Information This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the manual, may cause interference to radio communications. Split Pair Wires connected to wrong pins at connector or punchdown Open block. The the pin wires flash to indicate the fault.

To print the manual completely, please, download it. Fluie display with backlight. The shorted Figure 8 shows that wires 3 and 4 are crossed. This can occur if the port does not The tester can detect active and inactive Ethernet ports, as produce reflections.

Use the probe to isolate the tone source in the cable bundle or at the patch panel.

Results Screens for Individual Wire Pairs Mmicroscanner2 the display with glass cleaner and a soft, lint-free cloth. Use the tester to check for shorts. Got it, continue to print. The distance to a bridge tap is approximate because multiple reflections from the bridge tap interfere with length measurements. Diagnosing Wiremap Faults Appendix A lists the typical causes of wiremap failures.